Non-GI Systems

Chapter 11 covers non-GI detention and treatment systems. Each chapter identifies the objectives it can serve. Its waiver/variance entries describe the usual selection route; apply N.J.A.C. 7:8-5.3 and its conditional exceptions to the project. N.J.A.C. 7:8-5.3

Practice Main use and point to check
Blue roof Roof detention; ponding depth depends on structural calculations. Manual 11.1, p. 1
Extended detention Storage and slow release, including dry and underground arrangements. Manual 11.2, p. 1 Manual 11.2, p. 8
Manufactured treatment device Model-specific certified water-quality treatment, including hydrodynamic separation. Manual 11.3, p. 1
Membrane system or oil/grit separator Product descriptions that still need the exact device's verification and certification. Manual 11.3, p. 1
Underdrained sand filter Use Chapter 11.4 for the non-GI filter design. Manual 11.4, p. 1
Subsurface gravel wetland Planted cells and saturated gravel for water-quality treatment. Manual 11.5, p. 1
Non-GI wet pond Use Chapter 11.6 where the pond does not have the Chapter 10.5 GI configuration. Manual 11.6, p. 1

Chapter 11.2 explicitly includes subsurface vaults, pipes and stone-bed storage. Chapter 11.3 names hydrodynamic sedimentation and filtration devices; a different product label does not establish another approved class. Manual 11.2, p. 8 Manual 11.3, p. 1

Continue with GI selection and exceptions, runoff quantity control, BMP selection and maintenance planning.